Add to Cart
Huawei S5731 - S48S4X T4X - A1 48* 10 / 100 / 1000BASE - T switch
Technical specifications of the S5731-S48S4X
Item | Specification |
---|---|
Dimensions without packaging (H x W x D) [mm(in.)] | Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.40 in. x 16.54 in.) Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 448.0 mm (1.72 in. x 17.40 in. x 17.64 in.) |
Dimensions with packaging (H x W x D) [mm(in.)] | 185 mm x 650 mm x 550 mm (7.28 in. x 25.59 in. x 21.65 in.) |
Chassis height [U] | 1 U |
Weight without packaging [kg(lb)] | 5.12 kg (11.29 lb) |
Weight with packaging [kg(lb)] | 7.65 kg (16.87 lb) |
Typical power consumption [W] | 93.69 W |
Typical heat dissipation [BTU/hour] | 319.68 BTU/hour |
Maximum power consumption [W] | 128.89 (150 W AC or 180 W DC) 141.96 (600 W AC) |
Maximum heat dissipation [BTU/hour] | 439.79 (150 W AC or 180 W DC) 484.38 (600 W AC) |
MTBF [year] | 64.97 year |
MTTR [hour] | 2 hour |
Availability | >0.99999 |
Noise at normal temperature (acoustic power) [dB(A)] | 45.47 dB(A) |
Noise at normal temperature (acoustic pressure) [dB(A)] | 31.79 dB(A) |
Number of card slots | 0 |
Number of power slots | 2 |
Number of fans modules | 3 |
Redundant power supply | 1+1 Pluggable AC and DC power modules can be used together in the same switch, but power modules that use natural heat dissipation and power modules that use air cooling cannot be used together. |
Long-term operating temperature [°C(°F)] | -5°C to +45°C (23°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.) |
Short-term operating temperature [°C(°F)] | -5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.) |
Restriction on the operating temperature variation rate [°C(°F)] | When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). The device can work for a short period of time when the operating temperature is beyond the normal range, but the following conditions must be met:
If any of the preceding conditions is not met, the device may be damaged or an unknown error may occur. Devices cannot start when the temperature is lower than 0°C (32°F). The maximum transmission distance of an optical module used for short-term operation cannot exceed 10 km. |
Storage temperature [°C(°F)] | -40°C to +70°C (-40°F to +158°F) |
Long-term operating relative humidity [RH] | 5% to 95%, noncondensing |
Long-term operating altitude [m(ft.)] | 0-5000 m (0-16404 ft.) |
Storage altitude [m(ft.)] | 0-5000 m (0-16404 ft.) |
Power supply mode | Pluggable power supply |
Rated input voltage [V] |
|
Input voltage range [V] |
|
Maximum input current [A] | The current specifications depend on the pluggable power modules in use. For details, see the related power module specifications. |
Memory | 2 GB |
Flash memory | The physical space is 1 GB. You can run the display version command to view the actual available space. |
Console port | RJ45 |
Eth Management port | RJ45 |
USB | Not supported |
RTC | Supported |
RPS input | Not supported |
Service port surge protection [kV] | - |
Power supply surge protection [kV] |
|
Types of fans | Built-in |
Heat dissipation mode | Heat dissipation with fan, intelligent fan speed adjustment |
Airflow direction | Air intake from left,front and right, air exhaustion from behind |
PoE | Not supported |
Certification | EMC certification Safety certification Manufacturing certification |
S5731-S48S4X appearance
1 | Forty-eight 100/1000BASE-X ports | 2 | Four 10GE SFP+ ports |
3 | One console port | 4 | One ETH management port |
5 | One PNP button NOTICE: To restore the factory settings and reset the switch, hold down the button for at least 6 seconds. To reset the switch, press the button. Resetting the switch will cause service interruption. Exercise caution when you press the PNP button. | 6 | Ground screw NOTE: It is used with a ground cable. |
7 | Power module slot 1 | 8 | Power module slot 2 |