Add to Cart
Huawei S12700E-8 CloudEngine S12700E Series Switches
Appearance and Structure
The S12700E-8 chassis is 15 U high (1 U = 44.45 mm). When the chassis has no cable management frames installed, the dimensions (H x W x D) are 663.9 mm x 442 mm x 517.4 mm. When the chassis has cable management frames installed, the dimensions (H x W x D) are 663.9 mm x 442 mm x 585 mm.
shows the front structure of the S12700E-8 chassis.
1. Two MPUs | 2. Eight of the following service cards can be installed:
NOTE: The cards supported by a switch depend on the software version. For details, see Hardware Query Tool. | 3. Four SFUs | 4. A pair of mounting brackets NOTE: The mounting brackets are used to secure the chassis in a cabinet. |
5. Six power modules | 6. Two CMUs | 7. Front ESD jack NOTE: The ground terminal of an ESD wrist strap can be inserted into this jack. The ESD wrist strap can provide ESD protection when the chassis is reliably grounded. | 8. Cable management frames NOTE: The cable management frames separate cables on different cards and help route cables orderly. |
shows the rear structure of the S12700E-8 chassis.
S12700E-8 chassis structure (rear view)
1. Four Fan Module | 2. Rear ESD jack NOTE: The ground terminal of an ESD wrist strap can be inserted into this jack. The ESD wrist strap can provide ESD protection when the chassis is reliably grounded. | 3. JG ground terminal NOTE: The two-hole OT terminal of a ground cable can be connected to the screws to ground the chassis. | 4. Air filter NOTE: The air filter prevents dust from entering the chassis. |
5. A pair of removable handles NOTE: You can install these handles on two sides of the chassis to lift the chassis. | - | - | - |
Specifications of the S12700E-8 series switches
Item | Description |
---|---|
Number of LPU slots | 8 |
Number of MPU slots | 2 |
Number of SFU slots | 4 |
Number of fan slots | 4 |
Number of power module slots | 6 |
Number of CMU slots | 2 |
Port density per chassis | 384xFE, 384xGE, 384x10GE, 320x25GE, 192x40GE, 192x100GE |
Installation | The switch can be installed in an N66E or N68E cabinet, one cabinet for one chassis. |
Cluster switch system (CSS) | Service port clustering |
Maximum power consumption (fully configured) NOTE: The heat dissipation value of a chassis is equal to the current power consumption. | 6950 W |
Power specifications |
|
Dimensions (H x W x D, without rack-mounting brackets) |
|
Weight (empty/fully configured) | 42.5 kg/114 kg (93.7 lb/251.3 lb) |
Reliability and availability |
NOTE: The preceding values are calculated based on the typical configuration of the product. The actual values will vary depending on the modules installed on the product. |
Environment specifications |
|
Noise under normal temperature (sound power) | ≤ 78 dB(A) |
Certification |
|
Part number | 02115870 |